COMMON QUESTION

You are here:HomeSERVICES CENTRE > COMMON QUESTION

Management of water-based metal working fluid

Published:2014-11-26 16:10:36Sources:This siteViews:3968

Water-based metalworking fluid aims to to make its pH value, concentration ratio, amount ofbacteria and other technical indicators in the set range so as to prolong theservice life. Even if there is good performancewater-based metal working fluid, if there is no attention paid to dailymaintenance and management, it also cannot keep a long-term performance, andwill shorten the service life; and the general performance of the water-basedmetal working fluid, such as attention to maintenance management, also itsperformance to maintain long-term. Simple daily maintenance of water-basedmetal working fluid must be based on following methods:

Content of control

Index

Methods

Test frequency

Concentration

Recommended concentration

Handheld refractometer

1 time/day ( or longer)

pH value

>8.5 (depending on products)

Electronic pH meter, pH test paper

1 time/day ( or longer)

Rust

Level 0

Field product rust and

laboratory test

1 time/week ( or longer)

Anti-foaming performance

Foams not allowed to be piled up in great quantity

Visual inspection or laboratory test

1 time/week

Oil spill

Cutting fluid not allowed to be covered

Visual inspection

1 time/week

Metal fragments

Fragments not piled up

Visual inspection

1 time/day