COMMON QUESTION
You are here:Home > SERVICES CENTRE > COMMON QUESTIONManagement of water-based metal working fluid
Published:2014-11-26 16:10:36Sources:This siteViews:3968
Water-based metalworking fluid aims to to make its pH value, concentration ratio, amount ofbacteria and other technical indicators in the set range so as to prolong theservice life. Even if there is good performancewater-based metal working fluid, if there is no attention paid to dailymaintenance and management, it also cannot keep a long-term performance, andwill shorten the service life; and the general performance of the water-basedmetal working fluid, such as attention to maintenance management, also itsperformance to maintain long-term. Simple daily maintenance of water-basedmetal working fluid must be based on following methods:
Content of control | Index | Methods | Test frequency |
Concentration | Recommended concentration | Handheld refractometer | 1 time/day ( or longer) |
pH value | >8.5 (depending on products) | Electronic pH meter, pH test paper | 1 time/day ( or longer) |
Rust | Level 0 | Field product rust and laboratory test | 1 time/week ( or longer) |
Anti-foaming performance | Foams not allowed to be piled up in great quantity | Visual inspection or laboratory test | 1 time/week |
Oil spill | Cutting fluid not allowed to be covered | Visual inspection | 1 time/week |
Metal fragments | Fragments not piled up | Visual inspection | 1 time/day |
Previous:Selection of metal working fluid